WebApr 14, 2024 · HIGHLIGHTS. who: Shang-xian Xu from the Department of Anesthesiology, Children`s Hospital of Soochow University, Zhongnan Steet, Suzhou, Jiangsu, China have published the research: Effect of esketamine vs dexmedetomidine adjunct to propofol sedation for pediatric 3Tesla magnetic resonance imaging: a randomized, double-blind, … http://www.hsrsna.com/student/BIS_Article.PDF
BIS monitoring versus clinical assessment for sedation in …
Webbis-: ( bis ), 1. Prefix signifying two or twice. 2. chemistry used to denote the presence of two identical but separated complex groups in one molecule. Compare: bi- , di- . [L.] WebBispectral index (BIS) monitoring, an objective measure of the patient's response to sedation, has been used in anesthesia for over a decade. This technology is finding its … son of sachin
Bispectral Index (BIS) Monitoring • LITFL • CCC Neurology
WebThe BIS™ system offers three choices of smoothing rates over which the BIS™ value is averaged. There are three default settings based on monitor mode. For Monitor Mode I … The BIS monitor provides a single dimensionless number, which ranges from 0 (equivalent to EEG silence) to 100. A BIS value between 40 and 60 indicates an appropriate level for general anesthesia , as recommended by the manufacturer. See more Bispectral index (BIS) is one of several technologies used to monitor depth of anesthesia. BIS monitors are used to supplement Guedel's classification system for determining depth of anesthesia. Titrating See more The bispectral index is a statistically based, empirically derived complex parameter. It is a weighted sum of several electroencephalographic subparameters, including a See more BIS monitoring is widely used in operating rooms and ICUs, as well as in emergency departments. Some of the benefits that have been attributed to it include: • Reduced time to extubation and discharge from the operating room and PACU See more The BIS was introduced by Aspect Medical Systems, Inc. in 1994 as a novel measure of the level of consciousness by algorithmic analysis of a patient's electroencephalogram during general anesthesia. This is used in conjunction with other … See more Some of the limitations of this form of processed EEG monitoring are: • Unreliability with certain drugs, such as ketamine, nitrous … See more The BIS is an electroencephalogram-derived multivariant scale that, when a drug such a propofol is used, correlates with the metabolic … See more • Anaesthetic machine • Entropy monitoring • Evoked potentials • Respiratory monitoring • Spectral edge frequency See more WebBIS™ monitoring technology provides additional information to assess patient response and sedation level — and improves the application of anesthesia through: … small octopus in lab escaping tank