WebApr 3, 2024 · Teh bonding jumper shall be not smaller than 6AWG copper wire or equivalent. Gas piping systems that contain one or more segments of CSST. There needs to be a separate bonding wire connected either to the rigid gas piping before the CSST, or directly to one of the CSST nuts. Web• All CSST manufactured by Pro-Flex, LLC shall be bonded in accordance with the national model codes and these instructions. If there is an inconsistency between these instructions and local codes, the local codes shall control • There are no additional bonding requirements for Flak Jacket TM CSST set forth in the
Grounding & bonding of electrical systems NFPA
The grounding electrode system includes all of the grounding electrodes available and the grounding electrode conductor(s). All electrodes used must be bonded together into one common grounding electrode system in accordance with IFGC Section 310.2.3/IRC Section G2411.2.3. A separate grounding … See more The 2024 International Fuel Gas Code (IFGC) and International Residential Code (IRC) have reaffirmed (without any modifications) the requirements for the electrical protection of corrugated stainless steel tubing (CSST). … See more Arc-resistant (black) CSST is characterized by a thick black jacket or a multi-layer black jacket system. The single-layer black jacket is designed to absorb arcing energy … See more Existing steel or copper piping systems must be retroactively bonded when modified by adding yellow (non-arc-resistant) CSST to the system regardless of the length of … See more WebElectrical Bonding of Gastite CSST, in the January 2013 Gastite Design & Installation Guide, based on updates to 2015 NFPA 54 sec. 7.13.2, and 2015 IFGC sec. 310.1.1. Direct bonding of Gastite yellow CSST is required for all gas-piping systems incorporating Gastite CSST whether or not the connected gas equipment is electrically powered. c++ typedef with template
CSST bonding methods Mike Holt
WebOct 22, 2012 · Proposals to include specific bonding requirements for CSST gas piping systems in the 2011 NEC were rejected by NEC Code-Making Panel 5 on the grounds that lightning protection for gas piping systems is beyond the scope of the NEC. “The mitigation of the effects of lightning is a design option,” reads the rejection. WebWhen CSST is damaged, it can leak gas and cause an explosion and/or a fire. To the best of my knowledge, all manufacturers of CSST began implementing specific bonding requirements around 2007. Of course, proper bonding won't make CSST immune to damage from a nearby lightning strike, but it will reduce the risk of damage. WebOct 22, 2012 · Proposals to include specific bonding requirements for CSST gas piping systems in the 2011 NEC were rejected by NEC Code-Making Panel 5 on the grounds … easily tabs